General parameters |
Type |
AL17F MP100 |
Band |
17 GHz |
Band |
License free |
Frequency range (GHz) |
17.100 - 17.300 |
Duplex spacing (MHz) |
140 or software configurable |
Channel bandwidth (MHz) |
3.5 to 28 |
Modulation scheme |
QPSK to 128QAM |
Transmission capacity (Mbps) |
5 to 100 full duplex (10 to 200 aggregate) |
Frequency stability |
< 10 ppm |
Forward error correction FEC |
Reed-Salomon |
System configurations |
1+0 |
Radio Parameters |
Bandwidth / modulation |
Transmission capacity full duplex (Mbps) |
Receiver sensitivity for 10-6 (dBm) |
Output power (dBm)
|
3.5 MHz / QPSK |
5 |
-97 |
-24 to +12 |
3.5 MHz / 16QAM |
11 |
-89 |
-24 to +12 |
3.5 MHz / 32QAM |
14 |
-86 |
-24 to +12 |
3.5 MHz / 64QAM |
16 |
-83 |
-24 to +5 |
7 MHz / QPSK |
10 |
-94 |
-24 to +12 |
7 MHz / 16QAM |
19 |
-88 |
-24 to +12 |
7 MHz / 32QAM |
25 |
-83 |
-24 to +12 |
7 MHz / 64QAM |
30 |
-80 |
-24 to +5 |
7 MHz / 128QAM |
35 |
-76 |
-24 to +5 |
14 MHz / QPSK |
17 |
-91 |
-24 to +12 |
14 MHz / 16QAM |
39 |
-84 |
-24 to +12 |
14 MHz / 32QAM |
50 |
-81 |
-24 to +12 |
14 MHz / 64QAM |
61 |
-77 |
-24 to +5 |
14 MHz / 128QAM |
72 |
-73 |
-24 to +5 |
28 MHz / QPSK |
34 |
-88 |
-24 to +12 |
28 MHz / 16QAM |
77 |
-81 |
-24 to +12 |
28 MHz / 32QAM |
100 |
-78 |
-24 to +12 |
Automatic power control |
ATPC |
Adaptive coding and modulation |
ACM |
User interfaces |
Terminal box / protected |
ALM100 / ALS1-2FETH |
Line2 |
100Base-TX / 10Base-T, connector RJ-45 on terminal box |
Line3 |
100Base-TX / 10Base-T, connector RJ-45 on terminal box |
Maximal packet length |
1540 bytes |
Supports |
VLAN, Auto Negotiation or manual setting 100 / 10 and Full / Half Duplex, Flow Control, Auto MDIX, Master / Slave |
Control and diagnostic system |
Management port |
Ethernet NMS separately or together with user data with possibility of VLAN separation |
Management port |
RS232 connector on ODU for direct NMS connection |
Supports |
SNMP v1 |
ODU connection |
Cable type |
S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box |
Cable length |
Up to 100 m for 100Base-TX and up to 250 m for 10Base-T |
Antennas |
0.35 m gain mid band (dBi) |
32 |
0.65 m gain mid band (dBi) |
38 |
0.90 m gain mid band (dBi) |
41 |
1.20 m gain mid band (dBi) |
43 |
Class |
ETSI Class 2 or 3 |
Polarization |
Dual |
Power supply |
Power supply |
48 V DC (36-72) |
Power consumption |
Up to 25 W |
Temperature range |
Outdoor unit |
-33 to +55 °C |
Protected terminal box |
-25 to +55 °C |
Dimensions (w x h x d) and weight |
Outdoor unit |
255 x 301 x 133 mm / 5.1 kg |
ALM100 |
87 x 36 x 91 mm / 0.25 kg |
ALS1-2FEth |
147 x 44 x 163 mm / 0.4 kg |
Antenna 0.35 m |
5.6 kg |
Antenna 0.65 m |
8.3 kg |
Antenna 0.90 m |
26 kg |
Antenna 1.20 m |
36 kg |